Schurter Motor Overloads

Schurter T11-T13 Motor Overload

Schurter T11-13 overloads are a compact design 1 pole thermal circuit breaker with threaded neck and quick connect push terminals for simple installation.

The T11-T13 series of circuit breakers for equipment is a line of small single pole push to reset overload protective devices. The trip mechanism is of the superior latch type meaning a high contact force can be maintained until the unit trips. This prevents electrical noise due to contact bounce and reduces the risk of contact welding which may occur with spring type mechanism.

The overload sensing is done with the aid of a thermal bimetal which has the advantage of being immune to high inrush currents and line transients.

All T11 and T13 units are positively trip free. The contacts will open and remain open during an overload.

Contacts cannot be held in the closed position and they will not close automatically even the closing command is maintained.
Dimensions
T11: 11 x 18 x 34
T13: 14 x 29 x 47

PVC protective cover available.

Part No.AmpsPriceQuantityAdd to Cart
311-14670-0151.5A$23.00
311-14670-022A$23.00
311-14670-033A$23.00
311-14670-044A$23.00
311-14670-055A$23.00
311-14670-066A$23.00
311-14670-077A$23.00
311-14670-088A$23.00
311-14670-099A$23.00
311-14670-1010A$23.00
311-14670-1111A$23.00
311-14670-1212A$23.00
311-14670-1313A$23.00
311-14670-1414A$23.00
311-14670-1515A$23.00
311-14670-1616A$23.00
311-14671-1717A$46.00
311-14671-1818A$46.00
311-14671-1919A$46.00
311-14671-2020A$46.00

Customer Reviews

Description

Schurter T11-T13 Motor Overload

Schurter T11-13 overloads are a compact design 1 pole thermal circuit breaker with threaded neck and quick connect push terminals for simple installation.

The T11-T13 series of circuit breakers for equipment is a line of small single pole push to reset overload protective devices. The trip mechanism is of the superior latch type meaning a high contact force can be maintained until the unit trips. This prevents electrical noise due to contact bounce and reduces the risk of contact welding which may occur with spring type mechanism.

The overload sensing is done with the aid of a thermal bimetal which has the advantage of being immune to high inrush currents and line transients.

All T11 and T13 units are positively trip free. The contacts will open and remain open during an overload.

Contacts cannot be held in the closed position and they will not close automatically even the closing command is maintained.
Dimensions
T11: 11 x 18 x 34
T13: 14 x 29 x 47

PVC protective cover available.

Additional information

Part No.

, , , , , , , , , , , , , , , , , , ,

Amps

, , , , , , , , , , , , , , , , , , ,

Customer Reviews